Categories | Temperature Humidity Chamber |
---|---|
Brand Name: | komeg |
Model Number: | ES1000L |
Certification: | CE |
Place of Origin: | China |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 100 pcs/day |
Delivery Time: | 30 days after confirm the order |
Packaging Details: | Rigid foam and wooden box |
Heating: | High quality nickel-chromium alloy wire electric heaters, Non-contact control mode(SSR) |
Humidity uniformity: | 3.0%RH (no-load) |
Interior Material: | SUS 304 |
Heat up rate: | From -70℃ ↑ +180℃ Average 20℃/min No load .(According to IEC60068-3 Standard ) |
Humidity deviation: | ±3.0%RH(>75%RH) ±5.0%RH(≤75%RH) |
Packing: | Rigid foam and wooden box |
Capacity(L) | 1000L |
Temperature range | -40 °C ~ 100 °C |
Humidity range |
|
Alternating humidity |
|
Temperature fluctuation | ≤ ± 0.5 °C |
Temperature deviation: |
|
Humidity deviation | +2,-3%R·H |
Heating and cooling rate | 1.0 ~ 3.4 °C / min (linear adjustable) |
The time range | 0~9999H adjustable |
Power supply | 380V 50Hz |
Photovoltaic module constant temperature and humidity test chamber
meets
1. GB/T 19394.-2003 test;
2. GB/T9535.-1998 test;
3. GB/T6492-1986, GB/T6494,
4.GB/T6497, SJ/T2196;
5.IEC61345-1998; IEC61646,
6. IEC61215, etc. National standards, as well as other relevant
standards.
7. Strictly according to GB 10592-89 "Technical Conditions for High
and Low Temperature Test Chambers
8. GB 10586-89 "Damp Conditions for Hot and Cold Test Chambers" for
design and manufacture,
9. Conforms to IEC61215-2005 temperature. The corresponding
standard parameters for damp heat can
be used for various high and low temperature heat and humidity
alternating environments.
10. Solar Solar: IEC61215, UL1703, GB9535
11.Thin-film solar energy: IEC61646, GB18911
Main Material List imported from famous brand
Name | Brand |
Compressor | French Tecumseh |
Oil separator | American Emerson, ALCO, Temprite |
Plate heat exchanger | GEA, Xingsuneng, Guoxing |
press switch | Denmark DANFOSS, Saginomiya |
Condenser | Guangzhou Yongqiang, Klean Air |
Evaporator | Yongqiang |
Dry filter | Denmark DANFOSS, USA SPORLAN |
Capillary tube | KOMEG |
Expansion valve | Denmark DANFOSS, USA SPORLAN |
Magnetic valve | Japan SAGLNOMLYA |
Controller | KOMEG |
Residual current circuit breaker | Taiwan SHIHLIN |
No-fuse switch | French Schneider |
AC contactor | Japan French Schneider |
Features
Photovoltaic module constant temperature and humidity test chamber
meets the test index
1. Thermal cycle test
Photovoltaic modules circulate between -40°C±2°C and 85°C±2°C in a
test space where the wind speed
is not less than 2m·S-1.
2. Wet - cold (frozen) test
Place the PV module in the environmental chamber at room
temperature and complete 10 cycles. The
maximum and minimum temperatures shall be within ±2°C of the set
value, and at any temperature above
room temperature, the relative humidity shall be maintained within
±5%R·H of the set value.
Photos show