Sign In | Join Free | My chinacomputerparts.com
chinacomputerparts.com
Products
Search by Category
Home > Recycled Rubber >

FMS6000 photometric ,colormetric and electricity parameters Integrating System

Categories led lights test instruments and machine
Place of Origin: Guangdong China
Brand Name: LEADSMT
Certification: ISO9001:2000
Model Number: FMS6000
Power: Electronic
MOQ: 1 sets
Price: Negotiation
Packaging Details: Plywood case ,Carton & Film
Delivery Time: within 18ays after your advance deposit
Payment Terms: By T/T ,30% in Advance the balance before shippment
Supply Ability: 300 sets per month
Usage: Test leds and led lights
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    FMS6000 photometric ,colormetric and electricity parameters Integrating System

    1.FMS-6000 SPETRUM ANALYSIS SYSTEM

    1.rapid scanning technology, greatly improve the measurement speed, full spectrum scanning fastest time 10 s. Using spectral integral technology, achieve higher luminous flux measurement precision and linearity.


    2.monochromator spectrometer. Photomultiplier tube and other core components for the international famous brand high testing precision, high sensitivity, low stray light.

    2) the higher luminosity measurement spectra method was adopted to realize flux test precision. Photometric detector V (lambda) match of national level, the software embedded detector V (lambda) matching data.

    S basic measurement functions:

    1) to test relative spectral power distribution, chromaticity coordinates, dominant wavelength, peak wavelength, spectral purity, color temperature, color rendering index, half width, luminous flux (integral), radiation power, the red, the color tolerance, the parameters such as temperature, satisfies the requirement of CIE international commission on illumination light and color measurement.

    2) EPS software can automatically describe all kinds of light source light flux after starting/power/voltage/current curve of change over time.


    3. the main technical indicators:


    Items

    Statistic

    Notice

    Wavelength measurement range

    380nm-780nm


    Wavelength accuracy

    More or less 0.2nm


    Wavelength repeatability

    More or less 0.1nm


    Chromaticity coordinates(x,y) accuracy

    More or less 0.0003

    Under standard light source A

    Spectrum sampling interval

    5nm.1nm ,0.1nm


    Photometric system accurcy

    Class one


    Corelated color temperature measurement range

    1500k -25000k


    Corelated color temperature measurement accuracy

    More or less 0.3%

    Under standard light source A

    Luminous flux measurement range

    0.01lm~200000lm

    With suitable integrating sphere

    Color tolerance accuracy

    More or less 0.5


    Main wavelength range

    380nm-780nm


    Main wavelength accuracy

    More or less 0.2nm


    Color rendering range

    0-100

    More or less(0.3%+0.3)

    Temperature measurement range

    -10℃~80℃

    ±0.5℃


    2. 1.2 optical fiber

    Use for optical signal transmission integrating sphere between spectral analysis system and integrating sphere ,the high performance, light failure is small.


    3.Φ0.30m LED special integrating sphere and 1.5 m sphere

    Integrating sphere spraying process is good, high spectral reflectance, diffuse good performance, good stability for a long time, easy to clean, not yellow;

    Design in accordance with international standards, the ball can be loaded within two feet four feet/upright type LED lamp holder, it can realize the LED inside the ball 4 PI test. Integrating sphere side open Φ 60 mm hole and jig interface,use LED 2 PI outside of the ball test method ,the adapter supplier of various LED fixture (SMDLED, HPLED, etc.). Supplier provide free test is suitable for the 2 PI method Φ 30 high power LED (one) common fixture one only.


    4.FC-2 Light path converter

    when use big and small integrating sphere test share a spectrum analyzer, use the FC - 2 light path converter can avoid the fiber optic insertion and repeated calibration work, greatly raises ˎ ̥ high test efficiency and test personnel's workload. This design is convenient to use and accurate positioning.


    5.LSS05 General standard light source(spectral power distribution/flux)

    OSRAM lamp beads as original halogen lamp, 12 v / 5 w for spectral analysis system of color temperature (spectrum) calibration and photometer flux calibration (dissemination). High stability, high reproducibility, quantity can be traced back to the China metrology institute (NIM).


    6. integrating spheres

    together with the spectral analysis system or photometer ues for light luminosity chromaticity parameters testing systems.

    Integrating sphere spraying process is good, high spectral reflectance, diffuse good performance, good stability for a long time, easy to clean, not yellow;

    the ball inside the lamp holder: E40, match [E40 transfer E27, E14 transfer E27, E27 turn GU10 (vertical)], G13 / G5 (level);

    electrical interfaces: lamp holder bracket of samples and testing all fabric have power supply and voltage test side, the four wire method, can eliminate grew up with two wire system circuit current (especially the LED light source such as low voltage power line voltage loss caused by voltage test is inaccurate;

    way to open the door: unilateral rotating wheel/rail support type manually open and close;


    7.wp3005 precise digital display DC current and voltage stabilized supply


    1) voltage stability: ≤ 5×10-5 ,reading + 2 mv

    2) voltage range: 5 v / 10v / 25 v / 50 v;

    3) current stability: ≤ 1×10-4, readings +0.5mA ;

    4) range of ammeter range: 0.5A/1A/2.5A/5A

    5) voltage resolution :0.0001 V, (0.0000 V ~ 3.000 V); 0.001 V, (3.000 V ~ 50.000 V);

    6) voltage accuracy: + / - (0.02% reading+ 0.01%reading range + 2 words);

    7) current resolution: 0.0001 A, (0.0000 A to 0.0000 A);

    8)current accuracy: + / - (0.02%reading + 0.01%reading range + 2 words);

    9) maximum output power: 150 VA

    10)The maximum output voltage : 30 V

    11) the largest output current: 5 A


    8. UI2012 AC-DC electric parameter measurement instrument

    our window at the same time display voltage, current, power, power factor, with RS - 232 communication function;

    main technical indicators:

    1) can measure ac, dc, ac/dc signal;

    2) current and power with maximum,minmum limit alarm, especially suitable for the production line extensive testing,

    3) voltage range: AC: 5 ~ 600 v, DC: 1 ~ 600 v, current range: AC & DC: 0.005 ~ 20.00 A, range automatic conversion;

    4) accuracy: + / - (0.4%reading +0.1% reading range + 1 word)


    9.PDF-500 Precision frequency test power supply


    FDP series precision frequency test power supply is a kind of high power, low distortion, high stability of the power frequency pure sine wave power supply, integration of the source table. Adopt AC - DC - AC frequency conversion and digital waveform synthesis and waveform feedback, the integral period sampling of high-speed high precision, zero output impedance, isolated floating output, voltage current abnormal, and overheating protection, boot current limit and a series of advanced technology to ensure the accuracy of the power, pure nature, reliability and security. Use advanced 32-bit MCU control and measurement, RS - 232 communication can realize intelligent programmable output operations.


    the main technical indicators:

    1. The input voltage, AC 220 v/AC 110 v (internal change jumper wire), plus or minus 10% 1 phi 2 w 50/60 hz

    2. The output voltage: 0 ~ 150 v or 0 ~ 300 v two notches

    3. The output voltage temperature coefficient: plus or minus 0.2% / ℃

    4. The total harmonic distortion: ≦ 0.2% (at 50/60 hz) (ats Resister Load, PF = 1, THD -r measurement)

    5. The output line: 1 phi 2 w

    6. The output capacity: 500 VA

    7. The largest output current: test must meet the following conditions: AC power supply voltage plus or minus 5%, THD ≦ 2%, plus or minus 5% frequency;

    @ 120 v / 4.2 A;@ 240 v / 2.1 A;


    Power stability factor: + / - 0.2% (ACV + / - 10%; THD ≦ 2%; frequency + / - 5%) (@ 80% Fullscal output voltage, LOAD = 0 ~ 50%; PF = 1)

    9. The output frequency: 45 hz ~ 65 hz

    10. The frequency resolution(realization): 0.01 Hz;

    11. The frequency accuracy: + / - 0.05%


    12. photoelectric color measurement system cabinet (with door and panel)

    international standard open file size, the high quality cold rolling steel plate, the grey tones, well made. The FMS - 6000 / X - 5, WP3005, UI2012, FDP500 in this standard cabinets, make a complete set of photoelectric instrument as a whole the beauty is generous. Save a space, convenient reading operation, good resistance to electromagnetic interference. Cabinet install ac/dc switch, convenient wiring, easy to control operations. With excellent dustproof glass door, in line with international trends.

    Contact : tel : 86-13610497541 Skype : peter.huang187 Email : 493226540@qq.com


    Quality FMS6000 photometric ,colormetric and electricity parameters Integrating System for sale
    Send your message to this supplier
     
    From:
    To: Shenzhen Leadsmt Technology Co.,Ltd
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0