S / R / B Type Thermocouple Cable Copper Nickel Material -200-1300 °C Measurement Range

Categories Thermocouple Cable
Brand Name: OHMALLOY
Model Number: K-HP-HP-16
Certification: ISO9001-2008
Place of Origin: China(Shanghai)
MOQ: 100meters
Price: negotiable
Payment Terms: L/C, T/T, Western Union
Supply Ability: 500000meters per month
Delivery Time: 10 days
Packaging Details: 100m/spool, 305m/spool, 1000ft/spool, 1000m/spool
Material: Copper, Copper Nickel, Constantan, CuNi0.6, Alloy 11
Insulation: PVC. Fiberglass, PTFE, silicon rubber
Diameter: 16AWG, 18 AWG, 20 AWG, 24 AWG
Color: ANSI code, IEC code, GB/T standard
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    S / R / B Type Thermocouple Cable Copper Nickel Material -200-1300 °C Measurement Range

    S / R / B Type Thermocouple Cable Copper Nickel Material -200-1300 °C Measurement Range


    Specifications
    1. Style:Extension Wire
    2.Thermocouple copper wire
    Thermocouple copper wire Classification
    1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
    2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.

    Thermocouple variety and index


    Thermocouple Variety and Index

    Variety

    Type

    Measurement Range(°C)

    NiCr-NiSi

    K

    -200-1300

    NiCr-CuNi

    E

    -200-900

    Fe-CuNi

    J

    -40-750

    Cu-CuNi

    T

    -200-350

    NiCrSi-NiSi

    N

    -200-1300

    NiCr-AuFe0.07

    NiCr-AuFe0.07

    -270-0

    3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire

    Dimensions / Tolerance mm ) : 4.0+-0.25


    Color code & initial calibration tolerances for thermocouple wire:

    Thermocouple TypeANSI Color CodeInitial Calibration Tolerances
    Wire AlloysCalibration+/-
    Conductor
    JacketTemperature RangeStandard
    Limits
    Special
    Limits
    Iron(+) vs.
    Constantan(-)
    JWhite/RedBrown0°C to +285°C
    285°C to +750°C
    ±2.2°C
    ± .75%
    ±1.1°C
    ± .4%
    CHROMEL(+) vs.
    ALUMEL(-)
    KYellow/RedBrown-200°C to -110°C
    -110°C to 0°C
    0°C to +285°C
    285°C to +1250°C
    ± 2%
    ±2.2°C
    ±2.2°C
    ± .75%
    ±1.1°C
    ± .4%
    Copper(+) vs.
    Constantan(-)
    TBlue/RedBrown-200°C to -65°C
    -65°C to +130°C
    130°C to +350°C
    ± 1.5%
    ±1°C
    ± .75%
    ± .8%
    ± .5°C
    ± .4%
    CHROMEL(+) vs.
    Constantan(-)
    EPurple/RedBrown-200°C to -170°C
    -170°C to +250°C
    250°C to +340°C
    340°C+900°C
    ± 1%
    ±1.7°C
    ±1.7°C
    ± .5%
    ±1°C
    ±1°C
    ± .4%
    ± .4%


    Color Code & Initial Calibration Tolerance for Extension Wire:

    Extension typeANSI Color CodeInitial Calibration Tolerances
    Wire AlloysCalibration+/-
    Conductor
    JacketTemperature RangeStandard
    Limits
    Special
    Limits
    Iron (+) vs. Constantan(-)JXWhite/RedBlack0°C to +200°C±2.2°C±1.1°C
    CHROMEL (+) vs. ALUMEL (-)KXYellow/RedYellow0°C to +200°C±2.2°C±1.1°C
    Copper(+) vs. Constantan(-)TXBlue/RedBlue-60°C to +100°C±1.1°C± .5°C
    CHROMEL(+) vs. Constantan(-)EXPurple/RedPurple0°C to +200°C±1.7°C±1.1°C


    PVC-PVC Physical Properties:

    CharacteristicsInsulationJacket
    Abrasion ResistanceGoodGood
    Cut Through ResistanceGoodGood
    Moisture ResistanceExcellentExcellent
    Solder Iron ResistancePoorPoor
    Service Temperature

    105ºC continuous

    150ºC single

    105ºC continuous

    150ºC single

    Flame TestSelf-extinguishingSelf-extinguishing