Country/Region | china |
---|---|
Company | Xi'an Rapid Nav M&C Co.,Ltd |
Categories | Lab Measuring Instruments |
Telephone | +86 2982501710 |
ICP License | Issued by the Chinese Ministry |
Company Info. |
Xi'an Rapid Nav M&C Co.,Ltd |
View Contact Details |
Product List |
Specifications | LE-60-F | Remarks | |
Performance | |||
Accuracy (°) | 0.1 | at20° (at 25°C) | |
Angular Range (°) | 75 | From horizontal | |
Angular Drift w/Temp (°) | 0.7 | Up to20° Tilt | |
Angular Resolution (°) | See Table 1 | ||
Null Angular Offset (°) | < 0.5 | Actual value provided w/sensor | |
Non-Linearity (± 45°) (%) | < 0.3 | Measured at 25O C | |
Transverse Sensitivity (%) | 1 | Typical | |
Environment | |||
Temperature Range (°C) | -40 to +85 | ||
Electrical | |||
RS-232 Interface (Baud) | 9600 | ||
Supply Voltage (Volts DC) | 8-30 | ||
Supply Current (mA) | 60 | ||
Physical | |||
Size | 4.02 x 2.26 x 1.24” (10.21 x 5.74 x 3.15 cm) | ||
Weight | 2.9 oz (90 gm) | ||
Cable Length (feet) | 2.5 | ||
Filter | Fc(Hz) | Tc(s) | Typical Resolution (o) |
0 | none | none | 0.320 |
1 | 12.5 | 0.025 | 0.101 |
2 | 9.9 | 0.029 | 0.091 |
3 | 5.0 | 0.042 | 0.064 |
4 | 2.5 | 0.074 | 0.045 |
5 | 1.2 | 0.14 | 0.032 |
6 | 0.64 | 0.26 | 0.023 |
7 | 0.33 | 0.52 | 0.016 |
8 | 0.17 | 1.03 | 0.012 |
9 | 0.09 | 2.05 | 0.009 |
Command | Function Description/Response |
R | Reset. Resets the LE-60-F firmware to default settings. An ASCII ‘H’ (72) is sent in response. |
G | Get Angle Data Packet. The LE-60-F returns its current angular
position. The data is in a 6 byte packet defined in Table 2 |
N<0-9> | Set Resolution Level. A 2 byte command sequence that configures the
LE-60-F internal digital filter. The second byte, an integer of
value 0-9, sets the level of filtering. |
C | Continuous Mode: Transfers packet continuously at maximum rate. |
S |
![]() |